Custom Code
main image 39
Title RS85 Prestige
Category General Imaging
System pitch

A Revolutionary Change in Advanced Diagnostics

RS85 Prestige has been revolutionized with novel diagnostic features across each application based on the preeminent imaging performance. The advanced intellectual technologies are to help you confirm with confidence for challenging cases, while the easy-to-use system supports your effort involved in the routine scanning.

Showroom
Nav
System benefits

Crystal Architecture

Crystal Architecture, an imaging architecture that combines CrystalBeam and CrystalPure, while based upon S-Vue Transducer, provides crystal clear image.

  • CrystalBeam is a new beamforming technology beneficial in delivering high-quality image resolution and increased uniformity of images.

Sophisticated 2D & Color Images processed by CrystalPure

CrystalPure imaging engine help you to make more confident diagnoses with fundamental 2D images and enhanced color performance. It also lessens the incidence of clutter and boosts the level of color signal processing.

Feature image 71
Description

Visualize attenuated shadow area

ShadowHDR™ selectively applies high-frequency and low-frequency of the ultrasound to identify shadow areas where attenuation occurs

Feature image 72
Description

Clarify blurred area to provide clearer images

HQ-Vision provides clearer images by mitigating the characteristics of ultrasound images that are slightly blurred than the actual vision.

Feature image 73
Description

Three dimensional-like visualization of blood flow

LumiFlow is a function that visualizes blood flow in three dimensional-like to help understand the structure of blood flow and small vessels intuitively.

Feature image 74
Description

Visualize slow flow microvascularized structures

MV-Flow visualizes microcirculatory and slow blood flow to display the intensity of blood flow in color. It is suitable for observation of microcirculatory blood flow and volume of slow blood flow.

Feature image 75
Description

Directional power Doppler to examine peripheral vessels

The function uses directional power Doppler technology, enabling you to examine even the peripheral vessels. It displays information on the intensity and direction of blood flow.

Feature image 76
Description

Suppresses speckle noise and enhances edge for dense expression

PureVision is an image processing function that outputs with a good uniformity and clear image by performing Speckle Noise Suppression and Edge Enhancement on B-mode.

Advanced Intelligence for Reliable Assessment

Our features enable healthcare professionals navigate and quantify ultrasound propagation in realtime, helping them to visualize and make their assessments with accuracy.

Feature image 77
Description

Hepato-renal index (bright comparison) with automated ROI recommendation

HRI (Hepato Renal Index) is an index to quantify steatosis of a liver by comparing echogenicity between liver parenchyma and renal cortex. EzHRITM places 2 ROIs on the liver parenchyma and renal cortex and provides HRI ratio.

Feature image 78
Description

Quantitative measurement of liver fat with ultrasound signal attenuation

TAI (Tissue Attenuation Imaging) provides quantitative tissue attenuation measurement to assess steatotic liver changes.

Feature image 79
Description

Quantitative measurement of liver fat with with ultrasound signal scatter distribution

TSI (Tissue Scatter distribution Imaging) provides quantitative tissue scatter distribution measurement to assess steatotic liver changes.

Feature image 80
Description

Semi-automated imaging reporting tool for breast assessment

The feature, which analyzes selected lesions in the breast ultrasound study and shows the analysis data, applies BI-RADS ATLAS* (Breast Imaging-Reporting and Data System, Atlas) to provide standardized reporting; and helps diagnosis with the streamlined workflow.

  • BI-RADS ATLAS: It is a registered trademark of ACR and all rights reserved by ACR.

Feature image 81
Description

Semi-automated imaging reporting tool for thyroid assessment

The feature, which analyzes selected lesions in the thyroid ultrasound study and shows the analysis data, provides standardized reporting based on the ATA*, BTA*, EU-TIRADS* and K-TIRADS* guidelines and helps diagnosis with the streamlined workflow.

  • ATA: American Thyroid Association
  • BTA: British Thyroid Association
  • EU-TIRADS: European Thyroid Imaging Reporting and Data System
  • K-TIRADS: Korean Thyroid Imaging Reporting and Data System

Feature image 82
Description

Non-invasive quantification method of tissue stiffness

S-Shearwave Imaging allows for non-invasive assessment of the stiffness of tissue/lesions in various applications such as breast, liver, MSK and prostate.The color-coded elastogram, quantitative measurements, dual or single display option, and user-selectable ROI functions are especially useful for the accurate diagnosis of breast and liver diseases.

Precise and Convenient Interventional Solutions

RS85 Prestige provides a broad range of precise fusion, guidance,and dedicated tools to support healthcare professionals strengthen their confidence in operating interventional procedures.

Description

S-Fusion™ for Liver
Intuitive multi-modality fusion imaging with high precision

S-Fusion™ enables simultaneous localization of a lesion using real-time ultrasound in conjunction with other volumetric imaging modalities. Samsung’s Auto Registration helps quickly and precisely fuse the images, increasing efficiency and reducing procedure time. S-Fusion™ enables precise targeting during interventional and other advanced clinical procedures.

Matching Auto

Matching Auto allows automatic initial registration by attaching external markers to the patient’s body before S-Fusion™ exam is processed, thus it helps quick and accurate exam.

Positioning Auto

Positioning Auto helps quick and efficient examination with one-step initial registration between CT/MR and ultrasound images by positioning the transducer in the patient’s pit of the stomach before patient scan.



S-Fusion™ for Prostate
Assists in precise targeting during prostate biopsies

S-Fusion™ for Prostate allows precise targeting during prostate biopsies. Based on 3D models created with MR data sets, S-Fusion™ for Prostate provides biopsy guidance to help safely navigate and target the prostate.

Feature image 84

Description

Auto Calibration

S-Fusion™ for Prostate supports a real-time auto calibration function that helps you perform more accurate and reliable procedures.

Feature image 85

Description

Deformation Correction

Deformation Correction is a feature to improve the accuracy of registration with MR image by correcting deformed prostate shape when transducer is compressed during the procedure and it is useful for targeted biopsy procedure.

Feature image 86

Description

3D Modeling

S-Fusion™ for Prostate allows safe navigation and precise targeting during prostate biopsies based on 3D models created from MR data sets, and also provides a function to report biopsy location.

Feature image 87

Enhanced Productivity and Facilitated Workflow

Collaborative solution and streamlined workflow of the RS85 Prestige will support your daily procedures
by reducing keystrokes and by combining multiple actions into one.

Description

 
SonoSync™
Real-time image sharing solution

SonoSync™is a real-time image sharing solution that allows collaborative communication and remote controllability for effective collaboration between physicians and sonographers at different locations. Apart from these, SonoSync™ has several other elegant features like marking, invitation, still image sharing, multi-user, and multi-view. SonoSync™ brings telesonography into reality.

SonoSync™ is an image sharing solution, not a diagnostic solution.

Feature image 89

Feature image 90
Description

EzPrep™
Automatic transducer setting tool based on the worklist

EzPrep™ is a function that automatically selects the transducer based on the worklist inputted in the ultrasound system and sets the preset of the selected transducer.

Description

RIS Browser

RIS Browser is a function that improves the workflow in the hospital by allowing access to RIS through the browser embedded in the system for the post process without any need to move to the PC after scanning.

Feature image 91

Clinical Images
Transducers
CA1-7A CA2-8A CA3-10A CF4-9 CA4-10M

CA1-7A

Application:

Abdomen, Obstetrics, Gynecology, Musculoskeletal, Pediatric, Vascular, Urology

CA3-10A

Application:

Abdomen, Obstetrics, Gynecology, Musculoskeletal, Pediatric, Vascular, Urology

CA2-8A

Application:

Abdomen, Obstetrics, Gynecology

CF4-9

Application:

Pediatric, Vascular

CA4-10M

Application:

Pediatric, Vascular

LA2-14A

Application:

Small parts, Vascular, Musculoskeletal, Abdomen

LA2-9A

Application:

Small parts, Vascular, Musculoskeletal, Abdomen

LA2-9S

Application:

Small parts, Vascular, Musculoskeletal, Abdomen

LA3-16A

Application:

Small parts, Vascular, Musculoskeletal

L3-12A

Application:

Small parts, Vascular, Musculoskeletal

LA4-18A

Application:

Small parts, Vascular, Musculoskeletal, Abdomen

LM4-15B

Application:

Small parts, Vascular, Musculoskeletal

LA3-16AI

Application:

Musculoskeletal

LA3-22AI

Application:

Small parts, Vascular, Musculoskeletal, Pediatric, Intraoperative

LM3-18

Application:

Small parts, Vascular, Musculoskeletal, abdomen

CV1-8A

Application:

Abdomen, Obstetrics, Gynecology

EV3-10B

Application:

Obstetrics, Gynecology, Urology

EA2-11AR*

Application:

Obstetrics, Gynecology, Urology

EA2-11AV*

Application:

Obstetrics, Gynecology, Urology

EA2-11B

Application:

Obstetrics, Gynecology, Urology

EV2-10A

Application:

Obstetrics, Gynecology, Urology

* Ergonomic Transducer (CA1-7S, EA2-11AR, EA2-11AV)

The new convex transducer design with a smooth and slim grip helps users to scan easily and comfortably.
The new endocavity transducer supports natural grip by moving the max width point to a more forward positionand also increased the length of the grip to allow balanced weight distribution.

PA1-5A

Application:

Cardiac, TCD, Abdomen

PM1-6A

Application:

Cardiac, TCD, Abdomen

PA3-8B

Application:

Cardiac, Pediatric, Abdomen

PA4-12B

Application:

Cardiac, Pediatric


CW6.0

Application:

Cardiac

DP2B

Application:

Cardiac

MMPT3-7

Application:

Cardiac

More Specs... 39