Custom Code
main image 280
Title V7
Category Cardiovascular
System pitch

All the key benefits you want


The V7 offers a fascinating performance and gives you the possibility to do
what you want with comprehensive tools that feature the latest innovations.

For instance, EzHRI™, TAI™, and TSI™ are advanced abdominal dedicated
diagnostic features, that help healthcare professionals make accurate clinical
decisions by quantifying fatty liver in real time.

Rich in features, V7's versatile system is capable of a wide range of clinical
applications that allow you to explore to the fullest.

Showroom
System benefits

Diagnose diverse and challenging clinical cases

The V7 comes with a variety of tools for diverse and challenging cases.
Healthcare professionals can execute targeted examinations with ease, using the necessary advanced features prepared in the right place.
Furthermore, various sophisticated 2D and color imaging features are supported for extraordinary image quality.

2D imaging

Color imaging

Diagnostic features

Enriched diagnostic features with accuracy and precision

The V7 system comes with advanced features that assist in precise diagnosis and increasing throughput.
The V7’s variety of features and user-friendly interface aid in significantly improving the healthcare professionals’ daily ultrasound examination experience.

Feature image 190
Description

Display and quantify tissuestiffness in a non-invasive method

S-Shearwave Imaging allows for non-invasive assessment of stiff tissues in various applications. The color-coded elastogram, quantitative measurements, display options, and user-selectable ROI functions are especially useful for accurate diagnosis of breast and liver diseases.

Feature image 191
Description

Quantitative measurement of liver fat with ultrasound signal

TAI™ (Tissue Attenuation Imaging) provides quantitative tissue attenuation measurement to assess steatotic liver changes.
TSI™ (Tissue Scatter distribution Imaging) provides quantitative tissue scatter distribution measurement to assess steatotic liver changes.

Feature image 192
Description

Hepato-renal index with automated ROI recommendation

HRI (Hepato Renal Index) is an index to quantify steatosis of a liver by comparing echogenicity between liver parenchyma and renal cortex.
EzHRI™ places 2 ROIs on the liver parenchyma and renal cortex and provides HRI ratio.

Description

Perform multi-modality fusion biopsies with high precision

S-Fusion enables simultaneous localization of a lesion using real-time ultrasound with other volumetric imaging modalities, enabling accurate targeting during interventional and other advanced clinical procedures. Samsung's new Auto Registration helps quickly and precisely fuse the images for increased efficiency.

Description

Contrast Enhanced Ultrasound

CEUS+ is a contrast enhancement imaging technology that utilizes the characteristics of ultrasound contrast agents. The microbubble contrast agent injected into the body through the vein or alike is subjected to perform nonlinear resonance due to stimulation of ultrasound energy. In addition to the nonlinear signal generated by this method, the ultrasound contrast image is implemented by using the harmonic signal and thus utilized for the diagnosis based on the contrast characteristics over time.

Feature image 195
Description

Quantify wall motion of the left ventricle

Strain+ is a quantitative tool for measuring global and segmental wall motion of the left ventricle (LV). In Strain+, three standard LV views and a Bull's Eye are displayed in a quad screen for easy and quick assessment of the LV function.

Description

Score and report wall motion to determine heart and blood vessel function

StressEcho package includes wall motion scoring and reporting. It includes exercise StressEcho, pharmacologic StressEcho, diastolic StressEcho and free programmable StressEcho.

Feature image 197
Description

Detect functional changes of cardiovascular vessels

ArterialAnalysis detects functional changes of vessels, providing measurement values such as the stiffness, intima-media thickness and pulse wave velocity of the common carotid artery. Since functional changes occur before morphological changes, this technology supports the early detection of cardiovascular disease.

Description

Measure IMT in one click

AutoIMT+ is a screening tool to analyze a patient's potential risk of cardiovascular disease. It allows easy intima-media thickness measurement of both the anterior and posterior wall of the common carotid by the click of a button.

Feature image 199
Description

An automated reporting tool for heart diagnosis

HeartAssist™, a feature based on Deep Learning technology, provides automatic classification of ultrasound image into measurement views required for heart diagnosis and provides measurement results.

Feature image 200
Description

Detect and track nerves automatically with AI technology

NerveTrack™, a feature based on Deep Learning technology, detects and provides information of the location of the nerve area in real-time during ultrasound scanning.

Description

Display needle tip clearly

With pinpoint precision, NeedleMate+ delineates needle location when performing interventions such as nerve blocks. Improved accuracy and efficiency in the procedure are possible with beam steering added to NeedleMate+.

Feature image 202
Description

Analyze selected breast lesionsand report breast assessment

S-Detect for Breast, which analyzes selected lesions in the breast ultrasound study and shows the analysis data, applies BI-RADS ATLAS* (Breast Imaging-Reporting and Data System, Atlas) to provide standardized reporting; and helps diagnosis with the streamlined workflow.
* It is a registered trademark of ACR and all rights reserved by ACR.

Feature image 203
Description

Analysis of selected thyroid lesion and reportingfor thyroid assessment

S-Detect for Thyroid, which analyzes selected lesions in the thyroid ultrasound study and shows the analysis data, provides standardized reporting based on the ATA, BTA, EU-TIRADS and K-TIRADS* guidelines; and helps diagnosis with the streamlined workflow.
* ATA: American Thyroid Association
  BTA: British Thyroid Association
  EU-TIRADS: European Thyroid Imaging Reporting and Data System
  K-TIRADS: Korean Thyroid Imaging Reporting and Data System

Extraordinary image quality delivers diagnostic confidence

Gain insight into complex issues with exceptional image quality and resolution by Samsung’s core imaging engine, Crystal Architecture™.

The proprietary technology combines enhanced 2D image processing and detailed color signal processing to optimize and refine the image. The cutting-edge V7 will provide outstanding image clarity for a confident diagnosis.

Feature image 225
Description

Enhance hidden structures in shadowed regions

ShadowHDR™ selectively applies high-frequency and low-frequency of ultrasound to identify shadow areas where attenuation occurs.

Feature image 226
Description

Clean up blurry areas in the image

HQ-Vision™ provides clearer images by mitigating the characteristics of ultrasound images that are slightly blurred than the actual vision.

Feature image 227
Description

Reduce noise to improve 2D image quality

ClearVision enhances the edge contrast and creates sharp 2D images for optimal diagnostic performance.

Feature image 228
Description

Visualize slow flow in microvascular structures

MV-Flow™ visualizes microcirculatory and slow blood flow to display the intensity of blood flow in color.

Feature image 229
Description

Show blood flow in vessels in a 3D like display

LumiFlow™ is a function that visualizes blood flow in 3 dimensional-like to help understand the structure of blood flow and small vessels intuitively.

Feature image 230
Description

Examine peripheral vessels with directional power Doppler

S-Flow™, a directional Power Doppler imaging technology, can help to detect even the peripheral blood vessels. It enables accurate diagnosis when the blood flow examination is especially difficult.

Clinical Images
Transducers

CA1-7S CA2-8A CA4-10M

CA1-7SD*

Application:

Abdomen, Obstetrics, Gynecology, Pediatric, Musculoskeletal, Vascular, Urology, Thoracic

CA3-10A

Application:

Abdomen, Obstetrics, Gynecology, Pediatric, Musculoskeletal, Vascular, Urology, Thoracic

CA4-10M*

Application:

Abdomen, Vacular, Pediatric

LA2-14A

Application:

Small parts, Vascular, Musculoskeletal, Abdomen, Pediatric, Thoracic

LA2-9A

Application:

Small parts, Vascular, Musculoskeletal, Abdomen

LA2-9S*

Application:

Small parts, Vascular, Musculoskeletal, Abdomen

L3-22

Application:

Musculoskeletal, Small parts, Vascular, Pediatric

LA4-18AD*

Application:

Small parts, Vascular, Musculoskeletal, Abdomen

LA3-22AI

Application:

Small parts, Vascular, Musculoskeletal, Pediatric, Intraoperative

CV1-8AD

Application:

Abdomen, Obstetrics, Gynecology, Urology

EV2-10A*

Application:

Obstetrics, Gynecology, Urology

EA2-11ARD*

Application:

Obstetrics, Gynecology, Urology

EA2-11AVD*

Application:

Obstetrics, Gynecology, Urology

miniER7*

Application:

Obstetrics, Gynecology, Urology

PA1-5APE*

Application:

Cardiac, Vascular, Abdomen, Pediatric, TCD, Thoracic

PA4-12B

Application:

Abdomen, Cardiac, Pediatric, Vascular, TCD

PA3-8B

Application:

Abdomen, Cardiac, Pediatric, Vascular, TCD


CW6.0

Application:

Cardiac

DP2B

Application:

Cardiac

MMPT3-7

Application:

Cardiac

* Ergonomic Transducer

The new convex transducer design with a smooth and slim grip helps users to scan easily and comfortably.
The new endocavity transducer supports natural grip by moving the max width point to a more forward positionand also increased the length of the grip to allow balanced weight distribution.

Ultra Compact Prostate Ultrasound Transducer

Samsung has developed miniER7, an ultra-mini caliber prostate transducer with minimal head size to reduce patients pain and discomfort* when performing prostate examinations.
More Specs... 280
Documents & downloads