5500 Automatic Reader

tld-5500_750x500
  Get near-tissue equivalent thermoluminescence dosimetry (TLD) performance with a high-capacity reader for all types of TLD elements and health physics applications. The Thermo Scientific™ HARSHAW TLD Model 5500 Automatic Reader provides unattended operation for up to 50 dosimeters and accommodate ...Read more

Model 5500 Readers


  • Description
  • Specifications

 

Get near-tissue equivalent thermoluminescence dosimetry (TLD) performance with a high-capacity reader for all types of TLD elements and health physics applications. The Thermo Scientific™ HARSHAW TLD Model 5500 Automatic Reader provides unattended operation for up to 50 dosimeters and accommodates TL chips, disks, rods and cubes in a broad variety of sizes. This reader is suitable for all kinds of applications that require TLD detectors. Clinical applications are: Radiotherapy planning verification, total body irradiation dose verification, critical organ dose verification, diagnostic dose studies including CT, and many others where measurement quality assurance is critical.

The HARSHAW TLD Model 5500 Manual Reader includes a carrier disk for up to 50 TL detectors, a linear, programmable contactless nitrogen heating system, and a cooled photomultiplier tube with associated electronics to measure the TL light output. The operational software, Thermo Scientific™ WinREMS™, which runs on a separate computer, provides the user interface, the reader control and the applications software.

  • Multiple, programmable, linear heating cycles including pre-read anneal, acquire and post-read anneal cycles.
  • Typical cycle time per detector: typically 30 seconds.
  • Heating temperature capability up to 400°C.
  • Thermoelectric PMT cooler for maximum gain stability.
  • Seven decade glow curve acquisition range.
  • Options include glow curve deconvolution software (WinGCF Software), various types of neutral density filter to extend the high measurement range, and TL element specific carrier disks for best possible reproducibility.
  • Warm-up time: 30 minutes.
  • Easy to operate, service and maintain.
  • Size: 38 × 46 × 48cm.
  • 40kg.

 

Dosimetry Performance Using LiF:Mg,Ti (TLD-100/600/700)

  • Nearly tissue equivalent.
  • Radiation types: photons (E>5keV), electrons (E>70keV), neutrons (from thermal energies up to ∽100MeV, TLD-600 only).
  • Measurement range: 10 µGy to 1 Gy (linear), 1 Gy to 20 Gy (supralinear).
  • Detection threshold: <10 µGy based on 2.26 standard deviations for 10 sequential readings of an unexposed dosimeter.
  • Repeatability: Less than 2% variation based on one standard deviation for 10 sequential measurements of 1 mGy 137-Cs.
  • Residual TL signal: <0.2% of reading.
  • Fading: <20% in 3 months without thermal treatment; <5% in 3 months using pre-read anneal or glow curve deconvolution software (WinGCF Software).
  • Batch uniformity: ±30% from the factory standard.
  • Reuse: typically %500.

 

Instrument Performance

  • Dynamic range: 7 decades.
  • HV stability: ±0.005% per hour, ±0.02% per 8 hours.
  • Linearity: better than 1%.
  • Test light: temperature-stabilized LED.
  • Electrical supply: selectable, 110/120VAC ±10%, 60Hz or 220/240VAC ±10%, 50Hz
  • Nitrogen supply:
    • Purified (99.995%), dry.
    • Pressure: 2.8 to 6.3kg/cm2.
    • Flow Rate: internally regulated to 400 liters/h if specified pressure is provided.
  • Operating temperature: 15° to 40°C.
  • Storage temperature: -10° to +60°C.
  • Humidity: Functions within specification after 24 hour exposure to 90% humidity and subsequent 6-hour recovery with use of the nitrogen supply.
  • Ambient light exposure: Functions within specifications when exposed to ambient light up to 1,000 Lux with cover on the reader.
  • Shock: Withstands a 1-cm drop onto a concrete surface.

 

Ordering Alerts

Computer requirements: Any commercially available PC system with Windows™ 7, XP, 2000, or NT 4. 32 bit OS only. RS232 strongly recommended. (Please contact your sales representative for approved USB to RS232 converters).

 

Compatible with

Thermo Scientific TLD Materials, Thermo Scientific TLD Accessories

 

Recommended for

Treatment planning verification, diagnostic dose studies, quality assurance, whole body dosimetry, extremity dosimetry, environmental dosimetry, high dose applications (radiation hardness testing), and many more.

 

 

Batch Uniformity ±30% from the factory standard
Description Model 5500 TLD Reader Instrument
Dose Range Measurement range: 10 µGy to 1 Gy (linear), 1 Gy to 20 Gy (supralinear)
Detection threshold: 10 µGy based on 2.26standard deviations for 10 sequential readings of an unexposed dosimeter
Dosimeter Reusability >500
Dynamic Range 7 decades
Flow Rate Flow Rate: internally regulated to 400 liters/h if specified pressure is provided
Height (English) 1.89 in.
Height (Metric) 48 cm
Humidity Functions within specifications after 24-hour exposure to 95% and subsequent 6-hour recovery
Linearity Better than 1%
PMTs Thermoelectric PMT cooler for Maximum gain stability
Radiation Type Photons, Electrons, Neutrons
Reference Light Temperature-stabilized LED
Repeatability for 1 mGy (100 mrad) 137 Cs doses, >2% standard deviation of 10 sequential measurements
Stability HV stability: ±0.005% per hour, ±0.02% per 8 hours
Operating Temperature (English) 59°F to 104°F
Storage Temperature (English) 14°F to 140°F
Operating Temperature (Metric) 15°C to 40°C
Storage Temperature (Metric) −10°C to 60°C
Time and Temperature Profiles Multiple, programmable, linear heating cycles include pre-read anneal, acquire and post-read anneal cycles; Typical cycle time per detector: typically 30 seconds
Power Supply 100/120/220/240 VAC
Weight (English) 88.18 lb.
Weight (Metric) 40 kg
Ambient Light Exposure Functions within specifications when exposed to ambient light up to 1000 Lux with cover on the reader
For Use With (Equipment) Thermo Scientific TLD Card Dosimeters, Thermo Scientific TLD Materials, Thermo Scientific TLD Accessories
Product Type Radiation Dosimeter Reader
Detector Type Thermoluminescence (TL) Detector
Sensitivity Dependent on config. Used
Unit Size Each